Bonding Jumper - B = Stud Size #8 Or #10, C = Stud Size 1/4", Last Number Indicates Length In Inches, Bonding Jumper Assembly
Detail | Characteristic |
CONDUCTOR FORM | STRANDED SINGLE CONDUCTOR |
CROSS SECTION OUTSIDE DIAMETER | 0.080 INCHES NOMINAL |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
LEAD OVERALL LENGTH | 9.000 INCHES MINIMUM AND 9.250 INCHES MAXIMUM |
LEAD PULL STRENGTH | 110.0 POUNDS |
MATERIAL DOCUMENT AND CLASSIFICATION | QQ-W-343,SOFT FED STD ALL MATERIAL RESPONSES CORE CONDUCTOR SINGLE CONDUCTOR |
MATERIAL | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
ROUND CONDUCTOR SIZE | 12 AWG SINGLE CONDUCTOR |
STRAND AWG SIZE PER CONDUCTOR | 36 SINGLE CONDUCTOR |
STRAND QUANTITY PER CONDUCTOR | 254 SINGLE CONDUCTOR |
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 96906 BOTH ENDS SINGLE CONDUCTOR |
TERMINAL LUG APERTURE SIZE | 0.196 INCHES 1ST END SINGLE CONDUCTOR |
TERMINAL LUG APERTURE SIZE | 0.262 INCHES 2ND END SINGLE CONDUCTOR |
TERMINATION TYPE | LUG TERMINAL W/MOUNTING HOLE BOTH ENDS SINGLE CONDUCTOR |
TEST DATA DOCUMENT | 96906-MS25083 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
Welcome Back
Winback Offer
Unit of Measure
Inventory |
N/A {0} |
Estimated Ship Date |
N/A {N/A} |
Inventory Note |
N/A Need additional stock? Call (877) 920-1876 or email |
Length |
N/A 9 in |
Industry Standards/Certification |
N/A MS25083 |
Weight |
N/A .005 lb |
Stud Size B |
N/A #10 #8 |
Stud Size C |
N/A 1/4 in |
NSN |
N/A 6150-00-265-6451 |
NIIN |
N/A 00-265-6451 |
Part # Unpunctuated |
N/A MS250832BC9 |
Minimum Order Note |
N/A Minimum order is 1. Must order in increments of 1. |
Note |
N/A Our inventory is extensive. The majority of the items listed in our catalog are stocked and available for immediate shipment. |
California Residents |
N/A Prop 65 Warning: This product may contain chemicals known to the State of California to cause cancer, and birth defects or other reproductive harm. |